<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22450</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Plate too small to run through the processor, please remove plate from unload table
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Remove plate from unload table.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error will be displayed if the plate is too small to run through the processor,
that is, if the plate is smaller that the distance between the rollers inside the
processor.  This error is generated to prevent plates from being stuck inside the
processor.
Verify that the value of the nvs "al prg" is set correctly.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The nvs "al prg" is not set correctly.
</Cause>
<Cause>
The plate is too small to run through the processor
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cfg_pw.xml</LinkAddress><LinkTitle>NVS: al pw</LinkTitle></Link>
<Link><LinkAddress>../error_messages/22451.xml</LinkAddress><LinkTitle>E_ALE2_PLATE_TOO_LARGE_FOR_CONVEYOR</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:08 2008 PST
</Updated>
<Links>
</Links>
</Error>